The use of ddimer immunoassays characterized by a wide linearity range i. If the d dimer test is positive, objective imaging has to be performed. So this study was carried out to evaluate the diagnostic accuracy of d dimer in suspected pulmonary embolism patients. A prospective observational study was conducted from january to october 2005 at an urban academic emergency department ed. Roche cobas h 232 ddimer method and sample collection6. Ddimer methods, informing them of the confusion regarding the type and magnitude of ddimer units and the common practice by laboratories of converting the units.
Systemic values of dd are an index of fibrin turnover in the circulation and a single measurement may be adequate to assess the fibrinolytic status. Elevated d dimer differential answers on healthtap. It reflects ongoing activation of the hemostatic system. Cutoff value of ddimer in pulmonary thromboembolism and pneumonia article pdf available in turkish journal of medical sciences 395 august 2009 with 830 reads how we measure reads. The eurolyser ddimer test allows quick and easy determination of the parameter at the point of care.
We use diagnostica stagos sta compact analyzers and their lia ddimer reagent. A study was undertaken to compare a clinicianperformed qualitative d dimer assay with the automated quantitative d dimer test. The clinical use of a ddimer assay semantic scholar. D dimer or d dimer is a fibrin degradation product or fdp, a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. Limitations a number of limitations of the use of d dimer for vte diagnoses are listed in table ii 4. Refer to the axsym system operations manual, section 2, for proper installation procedures. The d dimer test is only useful in the context of the clinicians pretest probability of a venous thromboembolic event. This is a blood test to look for a substance called d dimer. D dimer is a degradation product of crosslinked fibrin and is routinely used in diagnostic algorithms for venous thromboembolism vte. Doctors give unbiased, helpful information on indications, contraindications, benefits, and complications. Fibrinogen consists of two identical subunits that contain three polypeptide chains. Vidas ddimer exclusion iidex2 vidas ddimer exclusion ii is an automated quantitative test for use on the instruments of the vidas family for the immunoenzymatic determination of fibrin degradation products fbdp in human plasma sodium citrate using the elfa technique enzyme linked fluorescent assay. Innovance ddimer kit general information pathlabtalk. Ddimer determination is mainly used to exclude deep vein thrombosis of the leg and pulmonary embolism.
Ddimer in pregnancy normal pregnancy causes the ddimer concentration to increase by an mean absolute magnitude of 0. A positive test means you need more testing usually ultrasound or ct scan the d dimer can be useful, in low. It is so named because it contains two d fragments of the fibrin protein joined by a crosslink. The resulting change in turbidity of the sample is detected photometrically by a turbidimetric analyser. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert. The innovance ddimer is substantially equivalent to the vidas ddimer exclusiontm k040882 assay. The d dimer assay is specific for plasmin degradation of fibrin, as opposed to fdps, which indicate degradation of either fibrin or fibrinogen. Package insert ddimer fs english diasys diagnostic systems. Comparison of the simplify ddimer assay performed at the. An educational supplement prepared by alqep may 2006. Quantitative d dimer determination aids in detecting the. Klinik tany ve laboratuvar pratiuinde ddimer testi ddimer. Thermo scientific remel ddimer is a rapid latex agglutination test used for detection and semiquantitation of crosslinked fibrin degradation products in serum or plasma.
This means you can get a great many false positive tests abnormal test but no disease present. Each risk factor for vte can raise dd and they are numerous. Ddimer concentration may be determined by a blood test to help to help diagnose thrombosis. D dimer is an epitope resulting from the plasmin degradation of fibrin. Can not be used as the only diagnostic tool for vte can only be used to ruleout patients without vte d dimer test must be. The innovance ddimer method, like the vidas ddimer exclusiontm method, is intended for use in conjunction with a clinical pretest probability ptp assessment model to exclude pulmonary embolism pe disease.
This assay is a monoclonal anti d dimer antibody coupled to latex particles that forms high molecular weight immunocomplexes with d dimer in the test sample. Package insert instructions must be followed accordingly. Ddimer health encyclopedia university of rochester. Manufacturers were encouraged to contact their clients to promote the use of only the type and magnitude of ddimer units provided in the package insert. Alere triage meterpro ddimer method and sample collection iecdd. Ddimer hs 0020007700 english insert revision 042010 intended use hemosil ddimer hs is an automated latex enhanced immunoassay for the quantitative determination of ddimer in human citrated plasma on the acl toptm for use, in conjunction with a clinical pretest probability ptp assessment model to exclude. The degree of the turbidity caused by agglutination can be measured optically and is proportional to the amount of d dimer in the sample. Ddimer and high molecular weight fibrin degradation products. Diagnostic accuracy of ddimer assay in suspected pulmonary.
This crosslinkage only occurs in fibrin, but not in fibrinogen, so d dimer is a specific degradation product of fibrin. The reliability of the result of a measurement cannot be guaranteed when use excluding described use and dosage regimen. Ddimer and high molecular weight fibrin degradation products f ibrinogen is a blood protein from which fibrin clots are formed upon blood coagulation or thrombotic process. Apr 15, 20 innovance reagents are good for 4 weeks refrigerated in their original vials. The clinical use of a ddimer assay acute care testing. The immunofiltration d dimer assay could allow pointofcare testing for pulmonary embolism pe. D dimer proteins in the sample bind to the specific anti d dimer antibody, which is coated on latex particles, and causes agglutination. Ddimer is one of the smallest fibrin degradation products arising directly from the bodys natural mechanism to break down blood clots. Manual for a complete description of the quality control system. A normal ddimer result of 500 ngml or less fibrinogen equivalent units feu on the il ddimer hs500 kit has a negative predictive value of approximately 100%. This product has been tested and shown to be negative for hbs. Thus, the clinical use of d dimer requires a validated method. Roche cobas h 232 ddimer method and sample collection iecdd. Cutoff value of ddimer in pulmonary thromboembolism and.
Alere triage meterpro ddimer method and sample collection10. Purpose and scope the purpose of this document is to describe the procedure for performing a ddimer. Elevations of circulating ddimer have been described in patients with venous thromboembolism, including pulmonary embolism pe and deep venous. D dimer is the end product of degraded crosslinked fibrin, but it is a heterogeneous collection of fibrin fragments and thus not a welldefined analyte. Blood clots generally start to slowly break down after they are formed, and this process releases d dimer into the blood. Ddimer levels can be elevated in many clinical circumstances. With a high specificity the number of unnecessary radiological imagings can be diminished for the benefit of the patient and to improve logistics of the healthcare system. Is it acceptable to run tests using the original container and put them back in the fridge after running tests, in that way we will not waste reagents when reagents are just left in the machine. I would put more stock in the negative radiology findings.
Specimen hemolysis and ddimer elevation fritsma factor. The ddimer assay of the plasmas to be tested is automatically carried out by the. This package insert must be read carefully prior to product use. Kinetic measurement of the d dimer concentration at 700nm absorbance. Patients with vte have elevated d dimer d dimer assay can be useful in vte diagnosis assay can be cost effective the d dimer assay has important limitations. D dimer test performed and a negative test excludes vte with a high sensitivity. Copyrpiopghtpcnydevgpthyeay pcwkwpp original article never. Historically these disorders, when suspected, have been confirmed using imaging. The quidel triage ddimer test is a rapid, quantitative immunoassay to aid in assessing and evaluating patients with suspected disseminated intravascular. Axsym d dimer must only be used with axsym system software.
Venous thromboembolic disease deep vein thrombosis and pulmonary embolism can be a difficult clinical diagnosis. The use of d dimer immunoassays characterized by a wide linearity range i. Vidas ddimer exclusion ii, ddimer assay biomerieux clinical. A d dimer that is slightly elevated is so nonspecific that it is really not at all helpful is making a diagnosis of anything. This question arrived january 8 from twyla bader mt ascp, hemecoag supervisor at st. Ddimer is one of the products of clot breakdown that can be measured in the bloodstream. Deep venous thrombosis pulmonary embolism, ddimer and pointofcare howard j. Jan 04, 2010 ddimer is a fibrin degradation product, a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. Ddimer is the degradation product of crosslinked by factor xiii fibrin. Klinik tany ve laboratuvar pratiuinde ddimer testi ddimer testing in clinical diagnosis and laboratory practice tevfik noyan ordu. It is a crosslinked dimer of the two smallest fibrin degradation products, fragment d d. Ddimer quantitative turbidimetric latex assay for the measurement of ddimer. Alere triage ddimer test product insert pi, english quidel. Mar 31, 2007 first, many physiological and pathological conditions can increase plasma d dimer levels pregnancy, age, trauma, cancer, inflammation and several other clinical conditions.
It is so named because it contains two crosslinked d fragments of the fibrinogen protein. Vidas ddimer exclusion ii safe exclusion of venous thromboembolism. With a careful combination of clinical assessment and d dimer, vte can be excluded. Innovance reagents are good for 4 weeks refrigerated in their original vials. Normally, this protein is present in small amounts because there is a constant turnover of tiny clots forming and being broken down by the bodys natural processes. An elisa d dimer abstract venous thromboembolism vte remains the most common preventable cause of inhospital death and d dimer dd is one of the essential diagnostic tools for it.
Ddimer concentration by itself does not imply anything, which gives it a nonspecific character. Deep venous thrombosis pulmonary embolism, ddimer and point. D dimer is a protein fragment from the break down of a blood clot. This is dr sam goldhaber for the clot blog at on medscape, recording from the american college of cardiology scientific sessions in san diego.
401 912 84 1106 174 182 1187 726 469 935 1107 38 1310 527 1465 733 386 1260 333 1545 156 546 877 14 391 898 1454 1120 686 69 1115 162